Brownout backup

Power when the grid is down.

A normal solar system goes dark in a brownout. A battery changes that.

Updated November 2026

Illustration of a wall-mounted home battery in a dark room
Illustration, not a real installation.

Why plain solar goes dark.

Ordinary grid-tied inverters shut off during a blackout for safety (EnergySage).

Meralco checks this at commissioning: the system must disconnect within 2 seconds of a grid outage and reconnect after 10 minutes (anti-islanding).

1.9 million

Meralco customers hit on May 13, 2026.

After a Luzon red alert, Meralco dropped load in parts of Bulacan, Cavite, Laguna, Metro Manila, Quezon and Rizal (Daily Tribune). DOE projections show one possible red alert in Luzon and four in the Visayas into early 2027 (Philstar). The Visayas, not Luzon, is most at risk (PIA).

What keeps power on.

  • A hybrid inverter with batteries: some can keep running on solar when the grid is down (EnergySage).
  • Already have solar? The easiest route is often an AC-coupled battery with its own inverter (EnergySage).
  • On net metering, the battery and transfer switch must be declared. It is not automatically approved (Meralco).

Battery type matters in heat.

  • Usable depth of discharge: generally 80–95% for LiFePO4, often about 30–60% for lead-acid (Eway Energy, a vendor).
  • Each 8°C rise halves the life of a sealed lead-acid battery (BSLBATT, citing Battery University).

At a glance

Which set-up keeps power on
Grid-tiedHybrid + batteryAdded AC-coupled battery
In a blackoutShuts offSome keep running on solarBattery with its own inverter
UpfrontLowest of the threeMore than grid-tiedAdded to an existing system
With net meteringYesBattery must be declaredBattery must be declared

Sources: EnergySage, Meralco. Upfront order is relative only; no prices.

Questions

Will my solar panels work in a brownout?

Not with a plain grid-tied system: it disconnects within 2 seconds of an outage (Meralco). You need a battery set-up that can run without the grid.

Do brownouts happen in Cavite and Laguna?

Yes. On May 13, 2026, Meralco's load dropping hit about 1.9 million customers, including parts of Cavite and Laguna (Daily Tribune). The DOE says Luzon's risk is lower than the Visayas'.

How big a battery do I need?

It depends on what must stay on and for how long. Use our brownout battery calculator with your own appliances.

Ready to see your own numbers?